Related Experiment Video
Updated: Jul 13, 2025

Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
Experimental, analytical, and simulation studies of modified concrete mix for radiation shielding in a mixed
Islam M Nabil1,2, Moamen G El-Samrah3, Ahmed Omar3
1Physics Department, Faculty of Science, Fayoum University, Fayoum, Egypt. im2029@fayoum.edu.eg.
Abstract:
The current study assessed two concrete mixes prepared using dolomite and barite/limonite aggregates to shield against both energetic photons and neutrons. After that, a designed mix which comprised barite/goethite aggregates plus fine-powdered boron carbide additive, was proposed to improve the overall radiation shielding properties and in the same time, doesn't compromise or even improve the physic-mechanical properties of the mature concrete. The assessment started first with intensive experimental investigations to investigate the prepared mixes' shielding capabilities against both γ-rays and fast neutrons. Then, analytical computations were performed via number of reliable software programs such as; Phy-X, NXCom, MRCsC, JANIS-4, and MCNP5, in order to confirm the experimental results and to validate the created Monte-Carlo models. Finally, an intensive radiation shielding assessment for all concrete mixes understudy using, mainly, the validated MCNP models, was performed. The obtained results have revealed the superiority of barite mixes over the dolomite mix concerning attenuating photons moreover, the proposed designed mix has shown superiority over the other two prepared mixes considering shielding against; energetic photons, fast/thermal neutrons, and secondary emitted γ-rays, which nominates this mix to be a suitable universal shield that can be used even in mixed radiation fields.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Design Example: Managing Concrete Workability
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Biological Effects of Radiation
Permeability of Concrete
Waterproofing and Anti-Bacterial Admixtures in Concrete
Waterproofing admixtures render concrete hydrophobic,...