Related Experiment Video
Updated: Jul 12, 2025

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
A fully automated Lab-on-a-Disc platform integrated a high-speed triggered siphon valve for PBMCs extraction
Jiahao Zhang1, Junyu Ma2, Yang Xu3
1State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin, 130033, China; Key Laboratory of Optical System Advanced Manufacturing Technology, Chinese Academy of Sciences, Changchun Institute of Optics, Fine Mechanics and Physics, Changchun, Jilin, 130033, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
Abstract:
Human Peripheral Blood Mononuclear Cells (PBMCs) are isolated from peripheral blood and identified as any blood cell with a round nucleus that exhibits immune responses and undergoes immunophenotypic changes upon exposure to various pathophysiological stimuli. Obtaining high-recovery and clinical-grade PBMCs without decreasing cell viability and causing stress is crucial for disease diagnosis and successful immunotherapy. However, traditional manual PBMCs extraction methods rely on manual intervention with less recovery rate and reliability. In this study, we introduced a novel and efficient strategy for the fully automated extraction of PBMCs based on a Lab-on-a-Disk (LoaD) platform. The centrifugal chip used percoll as density gradient media (DGM) for separation and extraction on account of the density difference of cells in whole blood, without labeling and any additional extra cellular filtration or cell lysis steps. Above all, we proposed a high-speed triggered siphon valve, which was closed under the speed of cell sedimentation and subsequently opened by increasing speed to complete the extraction of PBMCs. It can avoid the problem that previous siphon valves rely on unstable hydrophilic surface treatment and prime under low/zero speed conditions. With valves and the clock channel integrated on the chip, users can achieve fully automated collection of PBMCs. Compared with the clinical laboratory results, the recovery rate of extracted PBMCs was 80 %. The experimental results prove that the high-speed triggered siphon valve improves the extraction efficiency of PBMCs. The robust chips, which are not only simple to manufacture and assemble but also stable and reliable to use, have great potential in biomedical and clinical applications.
More Related Videos
11:32A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
Published on: November 23, 2015
12:21A Versatile Automated Platform for Micro-scale Cell Stimulation Experiments
Published on: August 6, 2013