Related Experiment Video
Updated: Jun 25, 2026

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects
Published on: December 10, 2021
Lateral tarsal strip procedure: comparison of absorbable sutures and non-absorbable polypropylene suture. Does the
Malik Moledina1, Ibrar Ahmed2, Ananth Ranji1
1Department of Ophthalmology, Southend University Hospital, Southend, UK.
Background/Objectives:
To determine whether the success and complication rates of the Lateral Tarsal Strip (LTS) Procedure, when treating involutional ectropion/entropion, is influenced by the use of suture when attaching the tarsal strip to the periosteum.
Subjects/Methods:
Multi-centre retrospective comparative study of re-operation and complication rates (Recurrence, Dehiscence, Suture Infection, Granuloma, Haemorrhage, Residual-Lid Laxity, Suture Extrusion and Repeat Procedure) in LTS, between 01/01/2017 and 01/01/2022 who met the inclusion/exclusion criteria, for involutional ectropion/entropion using an absorbable polyglactin (vicryl) and non-absorbable polypropylene suture (prolene).
Results:
1079 operations in 891 patients (36% female, average age 81.4 years) were performed with an average follow-up of 1.785 years. 588 operations in 475 patients were performed using prolene whilst 491 procedures in 416 patients were performed using vicryl sutures. Of these, 61% were performed by a consultant surgeon in the prolene group compared to 49.7% in the vicryl group. Overall complication rates between prolene and vicryl were 24.7% and 29.7% (p = 0.061) respectively. Higher complication rates for post-operative residual lid laxity, granuloma and suture infection were greater in the vicryl group versus prolene (2.65% and 0.51% p = 0.004, 2.24% and 0.68% p = 0.03, 1.83% and 0.17% p = 0.007 respectively). Non-significant results for dehiscence or repeat procedures (2.24% and 2.21% p = 0.974, 6.72% and 9.01% p = 0.166 respectively).
Conclusions:
Both sutures are effective for the correction of involutional ectropion/entropion with LTS. Dehiscence and redo rates were not statistically significant. Nevertheless, the use of vicryl suture was found to be associated with a higher complication rate for: post-operative residual lid laxity, granuloma and suture infection.
Related Concept Videos
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Polymer Classification: Architecture
Polymer Classification: Stereospecificity
Pharmacokinetics in Obese Patients: Drug Absorption and Distribution
Site-Targeted Drug Delivery Systems: Polymeric Carriers