Related Experiment Video
Updated: Jul 12, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Gas chromatography-flame ionization detector for sweat based COVID-19 screening
Nuttanee Tungkijanansin1, Sorachar Phusrisom1, Kaywalee Chatdarong2
1Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
Abstract:
Simple approach for rapid screening of corona virus disease 2019 (COVID-19) has been developed. This applied gas chromatography-flame ionization detector (GC-FID) analyzing the potential compound marker in sweat samples obtained from COVID-19 positive and negative volunteers in Bangkok, Thailand. The samples were collected by using cotton rods for 15 min, heated at 90 °C for 5 min, and the volatile compounds in the headspace (HS) were injected (5.00 mL) at 150 °C and separated within 13.7 min. The marker peak was tentatively identified as p-cymene by the authentic standard injection and comparison with the GC-mass spectrometry (GC-MS) and comprehensive two-dimensional GC (GC × GC)-MS analysis. Possible mechanisms for the presence of p-cymene were proposed. The marker peak area thresholds were then varied and optimized via construction of the receiver operating characteristic (ROC) curve. With the optimum threshold, the established method offered the accuracy, sensitivity and specificity of 96 %. This method was insignificantly affected (p-value >0.05) by genders, body mass indices, ages, and use of deodorants as well as the p-cymene containing food. However, the performance could be affected by the population with personal hygiene or experiencing the microbiomes producing p-cymene.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Types of Detectors