Related Experiment Video
Updated: Jul 12, 2025

Isolation of Native Soil Microorganisms with Potential for Breaking Down Biodegradable Plastic Mulch Films Used in Agriculture
Published on: May 10, 2013
Single-use accessories and endoscopes in the era of sustainability and climate change-A balancing act
Zaheer Nabi1, Raymond S Y Tang2, Sridhar Sundaram3
1Asian Institute of Gastroenterology, Hyderabad, India.
Abstract:
Gastrointestinal (GI) endoscopy is among the highest waste generator in healthcare facilities. The major reasons include production of large-volume non-renewable waste, use of single-use devices, and reprocessing or decontamination processes. Single-use endoscopic accessories have gradually replaced reusable devices over last two decades contributing to the rising impact of GI endoscopy on ecosystem. Several reports of infection outbreaks with reusable duodenoscopes raised concerns regarding the efficacy and adherence to standard disinfection protocols. Even the enhanced reprocessing techniques like double high-level disinfection have not been found to be the perfect ways for decontamination of duodenoscopes and therefore, paved the way for the development of single-use duodenoscopes. However, the use of single-use endoscopes is likely to amplify the net waste generated and carbon footprint of any endoscopy unit. Moreover, single-use devices challenge one of the major pillars of sustainability, that is, "reuse." In the era of climate change, a balanced approach is required taking into consideration patient safety as well as financial and environmental implications. The possible solutions to provide optimum care while addressing the impact on climate include selective use of disposable duodenoscopes and careful selection of accessories during a case. Other options include use of disposable endcaps and development of effective high-level disinfection techniques. The collaboration between the healthcare professionals and the manufacturers is paramount for the development of environmental friendly devices with low carbon footprint.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Sustainable Development
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
PPE Use in Healthcare Settings II: Doffing
Environmental Applications of Microorganisms
Handwashing I: Introduction and Types of Equipment
Hand wash basins in clinical areas should have faucets that can be turned on and off without using the hands; that is, they should be non-touch or lever-operated....

