Concomitant ablation of atrial fibrillation: New pacemakers and early rhythm recovery
Andrei Churyla1, Patrick M McCarthy1, Jane Kruse1
1Division of Cardiac Surgery, Northwestern University Feinberg School of Medicine, Chicago, Ill; Bluhm Cardiovascular Institute, Northwestern Medicine, Chicago, Ill.
Objective:
New permanent pacemaker (PPM) implantation after concomitant atrial fibrillation (AF) ablation has been associated with surgical ablation (SA). We sought to determine factors for PPM use as well as early rhythm recovery.
Methods:
From 2004 through 2019, 6135 patients underwent valve surgery and were grouped: No AF (n = 4584), AF no SA (n = 346), and AF with SA (n = 1205) to evaluate predischarge PPM and 3-month rhythm recovery (intrinsic heart rate >40 beats per minute).
Results:
Overall, 282 (4.6%) patients required a predischarge PPM: atrioventricular node dysfunction in 75.3%, sick sinus syndrome in 19.1%, both (5%), and indeterminate (0.7%). Patients with AF had more PPMs: AF with SA (7.9%) versus AF no SA (6.9%) versus No AF (3.6%) (P < .001). For patients with AF, PPM rates were not significantly higher for ablation patients (7.6% SA vs 6.9% AF no SA; P = .56). There were differences in PPM by SA lesion set (biatrial 12.8%; left atrial only 6.1%; pulmonary vein isolation 3.0%; P < .001). Among patients with AF treated with 3-month PPM follow-up, rhythm recovery was common (35 out of 62 [56.5%]) and did not differ by lesion set. Rhythm recovery was seen in 63 out of 141 (44.7%) in the atrioventricular node dysfunction group versus 24 out of 35 (68.6%) in the sick sinus syndrome group (P = .011). In propensity score-matched groups, late survival was similar (P = .63) for new PPM patients.
Conclusions:
Avoiding conduction system trauma and delaying implantation reduces the need for postoperative PPM. Rhythm recovery within 3 months is frequent, especially for patients with sick sinus syndrome. A conservative approach to the implantation of a new PPMs is warranted.
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Dysrhythmias VI: Management of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiopulmonary Resuscitation III: AED Use
Cardiomyopathy V: Interprofessional Care
Cardiopulmonary Resuscitation IV: Pharmacological Management