A practical approach to interpretation of 18F-fluorodeoxyglucose positron emission tomography/computed tomography for
Reinhard Kloiber1, Hans Lafford2, Ingrid L Koslowsky1
1Department of Radiology, Foothills Medical Centre, University of Calgary, 1403 29 Street NW, Calgary, AB, T2N 2T9, Canada.
Objective:
18F-fluorodeoxyglucose-PET/CT is the imaging modality of choice for the diagnosis of postoperative spine infection. Published interpretation criteria are variable and often incompletely described. The objective was to develop a practical and standardized approach.
Materials And Methods:
Two-hundred-twenty-seven FDG-PET/CTs performed on 140 postoperative patients over a 7-year period were reviewed retrospectively. The presence or absence of infection was determined from clinical history, microbiology, other investigations, and clinical outcome during a minimum 6-month follow-up.
Results:
No activity attributable to normal healing was seen in the post-discectomy space or at the bone-hardware interface in the absence of a complication at any stage. Within the incision, activity from normal healing persisted for months. Wound infections were diagnosed clinically, and most had already been treated before FDG-PET/CT was done to assess deep structures. With proven infection, 95% of cases had activity in bone or soft tissue outside the surgical field. The remaining 5% had activity confined to the post-discectomy space. Sterile hardware loosening may cause elevated activity which remains confined to the bone/hardware interface. Pathogens are introduced directly at the time of surgery and may be avirulent resulting in indolent infection with low-grade activity. At the same time, activity from non-infectious causes can be intense. A semi-quantitative method using SUVmax performed poorly compared with assessment of the distribution of activity.
Conclusion:
These observations have been incorporated into a checklist which is now being used at the time of interpretation. The potential sensitivity and specificity in the diagnosis of infection are close to 100%.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET