Background:
Contamination of work surfaces by used laryngoscopes after endotracheal intubation is a serious infection control concern but no strategies are available to address it. We assessed if contamination of the surfaces after endotracheal intubation would be reduced when providers used a dedicated, self-erected, disposable plastic sleeve (BladePouch) to store the used laryngoscope as compared to using single gloves or double gloves and sheathing the laryngoscope with the outer gloves.
Methods:
Twenty participants were recruited including attending physicians, trainees and allied health care professionals. They performed endotracheal intubation on a mannequin with oral cavity coated with a dye and stored the used laryngoscope blade using single gloves, double gloves or BladePouch. Each participant used both direct and video laryngoscopes. Following intubation, dye contamination of gloves, gown and work surface was evaluated.
Results:
There was no difference in the contamination of gloves or gowns between the single gloves, double gloves or BladePouch groups. However, work surface contamination was significantly reduced when using BladePouch compared to single or double gloves (13% vs. 100% vs. 80% respectively, P<0.001). The odds of work surface contamination were significantly lower with BladePouch vs. single or double gloves, even when adjusted for intubation device, role and experience of participants with an adjusted odds ratio of 0.0054 (95% confidence interval: 0.0009-0.0314), P<0.001.
Conclusions:
In conjunction with standard precautions, the use of a dedicated plastic sleeve to store contaminated laryngoscope blade after endotracheal intubation may reduce the work surface contamination, independent of intubation device, role and experience of providers.
Related Concept Videos
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...