SISTINE 3.0: Wearable System for Remote Functional Assessment of Phlebopathics
Emanuele D'Angelantonio1,2, Leandro Lucangeli1,2, Federico Caramia2
1Technoscience - Parco Scientifico e Tecnologico Pontino, Italy.
Studies in Health Technology and Informatics
|October 23, 2023
Summary
The SISTINE 3.0 wearable system shows potential for remote patient monitoring. It can differentiate between individuals with phlebopathic diseases and healthy subjects during mobility tests.
Area of Science:
- Biomedical Engineering
- Clinical Diagnostics
- Wearable Technology
Background:
- Phlebopathic diseases are chronic conditions affecting patient health status and functional capacity.
- Remote monitoring systems are crucial for managing chronic conditions and assessing functional limitations.
Purpose of the Study:
- To evaluate the SISTINE 3.0 wearable system's ability to detect differences between patients with phlebological conditions and healthy individuals.
- To assess the system's utility in remote patient monitoring for phlebopathic diseases.
Main Methods:
- Development of the SISTINE 3.0 wearable system for remote patient monitoring.
- A cohort of twelve patients with phlebological conditions and five healthy subjects participated.
- Participants performed a 3-metres Timed-Up-Go (TUG) test while wearing the SISTINE 3.0 system.
Main Results:
- The SISTINE 3.0 system demonstrated potential in discriminating between participants with and without phlebological conditions.
- Key discriminating parameters included linear walking velocity and turning angular velocity.
- The system successfully captured biomechanical data during the TUG test.
Conclusions:
- The SISTINE 3.0 system is a promising tool for the remote monitoring and assessment of phlebopathic diseases.
- The system's ability to detect differences in gait parameters highlights its clinical potential.
- Further research can validate its efficacy in larger patient cohorts and diverse clinical settings.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
353
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
353
Assessing Blood pressure in the Leg
2.8K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
2.8K
Peripheral Artery Disease IV: Nursing Management
11
The nursing management of a patient with peripheral artery disease (PAD) begins with a thorough assessment of the patient’s health history and clinical manifestations.AssessmentHealth History: Evaluate the patient’s history of hypertension, hyperlipidemia, family history of cardiovascular issues, and lifestyle factors such as dietary patterns, smoking, and physical activity.Physical Examination:Assess the affected extremity for decreased or absent peripheral pulses,...
11