Related Experiment Video
Updated: Jul 12, 2025

Probing Nicotinic Acetylcholine Receptor Function in Mouse Brain Slices via Laser Flash Photolysis of Photoactivatable Nicotine
Published on: January 25, 2019
A colorimetric sensor with dual-ratio and dual-mode for detection of nicotine in tobacco samples
Jian Li1, Pengcheng Liang1, Huijuan Song1
1College of Chemistry and Materials Science, College of Agronomy, Hunan Agricultural University, Changsha 410128, PR China. hushiyu@stu.hunau.edu.cn.
Abstract:
Nicotine (NIC) is a harmful substance, drug, pesticide and chemical that is widely found in tobacco. It has carcinogenic, teratogenic and neurotoxic effects that have raised serious concerns. Herein, a colorimetric sensor with dual-ratio and dual-mode for the detection of NIC in tobacco samples was reported. The localized surface plasmon resonance signals of gold nanoparticles (AuNPs) and AuNPs-NIC are used as dual-ratio signals. The absorbance ratio of NIC to AuNPs or the absorbance ratio of NIC to AuNPs-NIC and the wavelength shift value of AuNPs-NIC are applied as dual-mode. Transmission electron microscopy, energy dispersive spectroscopy, dynamic light scattering spectroscopy, ultraviolet-visible spectrophotometry, cyclic voltammetry, and potentiostatic methods were used to characterize the sensor. Further analysis of NIC was conducted through morphological fitting and theoretical calculations. Under optimal conditions, the sensor shows a wide linear range of 5-500 μM. The detection limits for NIC are 2.48 μM, 1.63 μM and 1.34 μM, respectively. The experimental result shows that the dual-ratio signal of AuNPs and AuNPs-NIC has good selectivity and sensitivity, and can effectively reduce the interference of impurities on NIC detection. And the dual-mode of detection for NIC improves the accuracy and comparability of the result significantly. In addition, the proposed sensor was also applied to test NIC in tobacco samples with satisfactory recovery.
More Related Videos
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
08:47Spectral Confocal Imaging of Fluorescently tagged Nicotinic Receptors in Knock-in Mice with Chronic Nicotine Administration
Published on: February 10, 2012
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...