Related Experiment Video
Updated: Jul 12, 2025

Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
Murray law-based quantitative flow ratio to assess left main bifurcation stenosis: selecting the angiographic
Nozomi Kotoku1, Kai Ninomiya1, Daixin Ding2
1Department of Cardiology, University of Galway, University Road, Galway, H91 TK33, Ireland.
Abstract:
Murray law-based quantitative flow ratio (µQFR) assesses fractional flow reserve (FFR) in bifurcation lesions using a single angiographic view, enhancing the feasibility of analysis; however, accuracy may be compromised in suboptimal angiographic projections. FFRCT is a well-validated non-invasive method measuring FFR from coronary computed tomographic angiography (CCTA). We evaluated the feasibility of µQFR in left main (LM) bifurcations, the impact of the optimal/suboptimal fluoroscopic view with respect to CCTA, and its diagnostic concordance with FFRCT. In 300 patients with three-vessel disease, the values of FFRCT and µQFR were compared at distal LM, proximal left anterior descending artery (pLAD) and circumflex artery (pLCX). The optimal viewing angle of LM bifurcation was defined on CCTA by 3-dimensional coordinates and converted into a 2-dimensional fluoroscopic view. The best fluoroscopic projection was considered the closest angulation to the optimal viewing angle on CCTA. µQFR was successfully computed in 805 projections. In the best projections, µQFR sensitivity was 88.2% (95% CI 76.1-95.6) and 84.8% (71.1-93.7), and specificity was 96.8% (93.8-98.6) and 97.2% (94.4-98.9), in pLAD and pLCX, respectively, with regard to FFRCT. The AUC of µQFR for predicting FFRCT ≤ 0.80 tended to be improved using the best versus suboptimal projections (0.94 vs. 0.89 [p = 0.048] in pLAD; 0.94 vs. 0.88 [p = 0.075] in pLCX). Computation of µQFR in LM bifurcations using a single angiographic view showed high feasibility from post-hoc analysis of coronary angiograms obtained for clinical purposes. The fluoroscopic viewing angle influences the diagnostic performance of physiological assessment using a single angiographic view.
More Related Videos
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Mitral Stenosis I: Introduction