Related Experiment Video
Updated: Jul 12, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Long-term Outcomes of Revision Total Hip Arthroplasty Using a Modular Fluted Conical Femoral Stem
David T Wallace1, Nicholas E Ohly1, David J Allen1
1Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, Scotland.
Background:
This study presents minimum 6-year follow-up data on the survival and satisfaction of an uncemented modular revision femoral system, following on from our previously published earlier results.
Methods:
We retrospectively reviewed all revision hip arthroplasties performed at our institution between January 2005 and October 2012, using a single modular femoral revision system. Patient-reported outcomes were collected (satisfaction score and Oxford Hip Score). Preoperative and postoperative radiographs were reviewed for stem subsidence, and Kaplan-Meier analysis was performed for survival. A total of 115 femoral revisions were performed in 106 patients.
Results:
All-cause survival was 82% (95% confidence interval 74 to 91%) at 10.8 years, and 96% (95% confidence interval 90 to 100%) excluding septic failure. Of the 19 cases requiring reoperation, 16 were for infection, 2 for aseptic loosening, and 1 for mechanical failure. At final follow-up, 88.5% of patients were "satisfied" or "very satisfied".
Conclusions:
This study showed excellent clinical results of a commonly used revision hip stem with at least 10 years follow-up. Satisfaction rates were high, with few aseptic failures. Stem subsidence was more common in revisions for infection, but did not correlate with lower satisfaction scores.
More Related Videos
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022