Related Experiment Video
Updated: Jul 12, 2025

Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Effect of high-frequency oscillation on reduction of atelectasis in perioperative patients: a prospective randomized
Yuan-Jun Qin1, Yun-Qian Zhang1, Qi Chen1
1Department of Anesthesiology and Surgical Intensive Care Unit, Xinhua Hospital, Shanghai Jiaotong University School of Medicine, China.
Background:
Atelectasis affects approximately 90% of anaesthetized patients, with laparoscopic surgery and pneumoperitoneum reported to exacerbate this condition. High-frequency oscillation therapy applies continuous positive pressure pulses to oscillate the airway, creating a pressure difference in small airways obstructed by secretions. This process helps reduce peak airway pressure, open small airways, and decrease atelectasis incidence, while also facilitating respiratory tract clearance. This study examines the efficacy of high-frequency oscillation on reduction of atelectasis in laparoscopic cholecystectomy (LC) patients under general anaesthesia, evaluated using lung ultrasound.
Methods:
Sixty-four patients undergoing laparoscopic cholecystectomy were randomly divided into a control group and a high-frequency oscillation (HFO) group. Both groups underwent total intravenous anaesthesia under invasive arterial monitoring. The HFO group received a 10-minute continuous high-frequency oscillation therapy during surgery, while the control group received no intervention. Lung ultrasound evaluations were performed three times: five minutes post-intubation (T1), at the end of the surgery (T2), and before leaving the Post-Anaesthesia Care Unit (PACU; T3). Blood gas analysis was performed twice: prior to induction with no oxygen supply and before PACU discharge (oxygen supply off).
Results:
The HFO group displayed a significantly lower incidence of atelectasis at T3 (57.5% vs. 90.3%, OR 6.88, 95%CI (1.74 to 27.24)) compared to the control group. Moreover, the HFO group's PaO2 levels remained consistent with baseline levels before PACU discharge, unlike the control group. Although there was no significant difference in LUS scores between the groups at T1 (8.56 ± 0.15 vs. 8.19 ± 0.18, p = 0.1090), the HFO group had considerably lower scores at T2 (13.41 ± 0.17 vs.7.59 ± 0.17, p < 0.01) and T3 (13.72 ± 0.14 vs.7.25 ± 0.21, p < 0.01).
Conclusion:
Our study indicates that high-frequency oscillation effectively reduces atelectasis in patients undergoing laparoscopic cholecystectomy. Additionally, it can mitigate the decline in oxygen partial pressure associated with atelectasis.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Suctioning the Nasopharyngeal Airway
Equipment Required
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...