Related Experiment Video
Updated: Jul 12, 2025

Antimicrobial Characterization of Advanced Materials for Bioengineering Applications
Published on: August 4, 2018
Activity of antimicrobial examination gloves under realistic conditions: challenge not fulfilled
Eva-Maria Klupp1, Birte Knobling1, Gefion Franke1
1Department for Infection Prevention and Control, Institute for Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany.
Background:
Antimicrobial materials or surfaces are advertised as part of infection prevention bundles. However, the efficacy of such antimicrobial surfaces has not been sufficiently investigated in hospitals. In this study, the antimicrobial activity of examination gloves with light-activated antimicrobial properties against Gram-positive microorganisms was investigated modelling real live conditions.
Method:
In a standardized experimental set-up with dry and realistic contamination, the antimicrobial properties of gloves claiming light dependent antimicrobial activity against Gram-positive organisms were tested in comparison with conventional examination gloves. All gloves were contaminated through a standardized activity of the test persons for construction with contaminated building blocks. For contamination suspensions of Enterococcus faecium ATCC 6057, Acinetobacter baumannii (outbreak strain), methicillin resistant Staphylococcus aureus ATCC 43300 or E. faecium (VRE) patient isolate were dried on the surfaces. After the standardized activity, the gloves were held for 10 min in the light present in the room (bright conditions) and the grade of contamination was determined subsequently by quantitative culture. In one experimental series gloves were held in a dark box after contamination as a control (dark conditions).
Results:
The light intensity in all experiments under bright conditions was significantly above the limit value specified by the manufacturer for the activation of antimicrobial properties (> 500 lx). The mean values for experiments with antimicrobial active and non-active gloves were 955 and 935 lx, respectively. As claimed by the manufacture, the gloves showed no sufficient efficacy against A. baumannii under bright conditions. Against Gram-positive microorganisms such as E. faecium, E. faecium (VRE) and methicillin resistant S. aureus the gloves showed only very low antimicrobial activity with a reduction factor < 1 log10 even after 10 min in bright conditions. Interestingly, comparable results for experiments with A. baumannii and E. faecium were shown under dark conditions.
Conclusion:
The lack of activity of the active principle against Gram-negative microorganisms could be confirmed. The reduction factors of > 4 log10 within 5 min for Gram-positive microorganisms claimed for the product using a standard test procedure (ASTM D7907) could not be confirmed in a realistic experimental test set-up even after 10 min of light exposure. The effectiveness against Gram-positive microorganisms should be further investigated under realistic (dry) conditions, including patient care. At this stage, the use of supposedly antimicrobial gloves should not be recommended, as the belief in their efficacy may encourage the misuse of gloves.
Related Concept Videos
Hand hygiene
Hand washing...
Antimicrobial Effectiveness
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Surface Membrane Barriers
The outer layer of the skin, the epidermis, is a robust barrier comprising layers of closely packed keratinized cells. This dense arrangement prevents microbes from penetrating the body. The periodic shedding of epidermal cells...