Related Experiment Video
Updated: Jul 12, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Flexible bronchoscopic intubation through a supraglottic airway device: An evaluation of consultant anaesthetist
Christine N Svendsen1, Gine L Glargaard1, Lars H Lundstrøm1,2
1Department of Anaesthesiology, New North Zealand Hospital, Hillerød, Denmark.
Background:
Few clinical studies investigate technical skill performance in experienced clinicians.
Methods:
We undertook a prospective observational study evaluating procedural skill competence in consultant anaesthetists who performed flexible bronchoscopic intubation (FBI) under continuous ventilation through a second-generation supraglottic airway device (SAD). Airway management was recorded on video and performance evaluated independently by three external assessors. We included 100 adult patients undergoing airway management by 25 anaesthetist specialists, each performing four intubations. We used an Objective Structured Assessment of Technical Skills-inspired global rating scale as primary outcome. Further, we assessed the overall pass rate (proportion of cases where the average of assessors' evaluation for every domain scored ≥3); the progression in the global rating scale score; time to intubation; self-reported procedural confidence; and pass rate from the first to the fourth airway procedure.
Results:
Overall median global rating scale score was 29.7 (interquartile range 26.0-32.7 [range 16.7-37.7]. At least one global rating scale domain was deemed 'not competent' (one or more domains in the evaluation was scored <3) in 30% of cases of airway management, thus the pass rate was 70% (95% CI 60%-78%). After adjusting for multiple testing, we found a statistically significant difference between the first and fourth case of airway management regarding time to intubation (p = .006), but no difference in global rating scale score (p = .018); self-reported confidence before the procedure (p = .014); or pass rate (p = .109).
Conclusion:
Consultant anaesthetists had a median global rating scale score of 29.7 when using a SAD as conduit for FBI. However, despite reporting high procedural confidence, at least one global rating scale domain was deemed 'not competent' in 30% of cases, which indicates a clear potential for improvement of skill competence among professionals.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...