Related Experiment Video
Updated: Jul 12, 2025

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
Effect of skinfold thickness on arm venous access port in cancer patients
Zhimin Liu1, Laiyou Li2, Jiayin Liu1
1Department of Medical Oncology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
Background:
Currently, skinfold thickness in studies on arm venous access ports and the effect of venous access port application are unknown.
Materials And Methods:
A total of 256 cancer patients who underwent primary venous access port placement in the Fourth Hospital of Hebei Medical University from September 2022 to March 2023 were selected as the study subjects. Two hundred fifty-six patients were divided into normal skinfold thickness group and high skinfold thickness group according to skinfold thickness. The success rate of primary catheterization of arm venous port catheterization, catheterization operation time, catheterization length and incidence rate of adverse reactions were compared.
Results:
There was no significant difference in the basic data between the two groups. There was no significant difference in the success rate of primary catheterization between the two groups (p > 0.05), the catheterization operation time in the normal skinfold thickness group was significantly lower than that in the high skinfold thickness group (p < 0.05), the total length of the implanted catheter in the normal skinfold thickness group was significantly lower than that in the high skinfold thickness group (p < 0.05), and the incidence of adverse reactions in the normal skinfold thickness group was significantly lower than that in the high skinfold thickness group (p < 0.05).
Conclusion:
In cancer patients, skinfold thickness can significantly affect the application effect of arm venous port, and normal skinfold thickness for arm venous port has shorter operation time, total length of implanted catheter and lower incidence of adverse reactions.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Thrombosis IV: Nursing Management
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Pre-Procedural Guidelines for Assessing Blood Pressure
Hemodialysis I: Introduction
Venous Thrombosis III: Interprofessional Care