A machine learning approach for computation of cardiovascular intrinsic frequencies
Rashid Alavi1, Qian Wang2, Hossein Gorji3
1Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, California, United States of America.
Abstract:
Analysis of cardiovascular waveforms provides valuable clinical information about the state of health and disease. The intrinsic frequency (IF) method is a recently introduced framework that uses a single arterial pressure waveform to extract physiologically relevant information about the cardiovascular system. The clinical usefulness and physiological accuracy of the IF method have been well-established via several preclinical and clinical studies. However, the computational complexity of the current L2 optimization solver for IF calculations remains a bottleneck for practical deployment of the IF method in real-time settings. In this paper, we propose a machine learning (ML)-based methodology for determination of IF parameters from a single carotid waveform. We use a sequentially-reduced Feedforward Neural Network (FNN) model for mapping carotid waveforms to the output parameters of the IF method, thereby avoiding the non-convex L2 minimization problem arising from the conventional IF approach. Our methodology also includes procedures for data pre-processing, model training, and model evaluation. In our model development, we used both clinical and synthetic waveforms. Our clinical database is composed of carotid waveforms from two different sources: the Huntington Medical Research Institutes (HMRI) iPhone Heart Study and the Framingham Heart Study (FHS). In the HMRI and FHS clinical studies, various device platforms such as piezoelectric tonometry, optical tonometry (Vivio), and an iPhone camera were used to measure arterial waveforms. Our blind clinical test shows very strong correlations between IF parameters computed from the FNN-based method and those computed from the standard L2 optimization-based method (i.e., R≥0.93 and P-value ≤0.005 for each IF parameter). Our results also demonstrate that the performance of the FNN-based IF model introduced in this work is independent of measurement apparatus and of device sampling rate.
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring pulse
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...