Association of Patient Satisfaction with Cataract Grading in Five Types of Multifocal IOLs
Sana Niazi1, Zisis Gatzioufas2, Sorcha N Dhubhghaill3,4
1Translational Ophthalmology Research Center, Tehran University of Medical Science, Tehran, Iran.
Introduction:
This study investigated patient satisfaction levels in five premium intraocular lenses (IOLs). A secondary aim was to determine whether patient satisfaction was associated with the cataract grade before lens surgery.
Methods:
In this multicenter prospective comparative study, 164 patients from diverse backgrounds underwent cataract surgery and were assigned for identical bilateral implantation of multifocal IOLs. In addition to visual performance, quality of life was measured using the National Eye Institute Refractive Error Quality Of Life Instrument (NEI-RQL 42) scoring questionnaire. The Sirius Scheimpflug Analyzer was used to evaluate the posterior cornea and aberrations. Finally, the association of patient satisfaction reports with the Pentacam Cataract Grading Scale (PCGS) and Lens Opacities Classification System (LOCS III) was evaluated.
Results:
A considerable subjective improvement was observed in uncorrected far, near (40 cm), and intermediate (60 cm) visual acuity in the five groups (P values < 0.001). A significant difference was observed in mesopic and photopic contrast sensitivity between Symfony, Trinova, and AT LISA at the spatial frequency of 12 cycles per degree, favoring Symfony (P < 0.001). PanOptix users had considerably lower mean coma values (P < 0.001), while AT LISA users had lower mean spherical aberrations (P = 0.009) compared to the other groups. No additional safety concerns relating to IOLs were recorded. Mean satisfaction had a high correlation with LOCS and Pentacam Nuclear Staging (PNS) in each lens group, e.g., correlation coefficient and P value for AT LISA were respectively r = 0.99, P < 0.001 and r = 0.97, P = 0.004.
Conclusion:
Despite discrepancies between groups of lenses, most patients who received multifocal IOLs reported satisfaction at more than 3 years after the initial operation. A growing number of patients with cataracts are seeking spectacle-free vision with presbyopia-correcting IOLs. Hence, the high satisfaction rate among patients with cataract could indicate the value of offering a wider range of available lenses.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
05:19Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
Published on: December 1, 2023
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
