Related Experiment Video
Updated: Jul 12, 2025

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Five Steps for the Maintenance and Interception of Complications in Zygomatic Implants
Consuela Sanavia1, Edoardo Vallerga2, Fanny Alessi3
1Department of Surgical Sciences, University of Genoa, 16126 Genoa, Italy.
Abstract:
Zygomatic implants are used for the rehabilitation of the upper jaw of patients with severe and moderate bone atrophy. Possible post-surgical complications include soft tissue dehiscence, sinusitis, and prosthodontic fractures, and maintaining an accurate control is crucial. Additionally, zygomatic implants have a unique peri-implant anatomy, making traditional periodontal parameters unsuitable. The present paper aims to provide guidelines for the maintenance and interception of complications in patients rehabilitated with these kinds of implants. The proposed protocol includes: 1. intra/extraoral and temporo-mandibular joint examination; 2. soft tissue and transmucosal path observation with magnifiers; 3. peri-implant health indices and digital stimulation of tissues; 4. examination of prosthodontic devices; and 5. photographic recording. These steps facilitate the comprehensive evaluation and monitoring of clinical conditions of zygomatic-supported rehabilitations, including dehiscence and occlusal wear during follow-up appointments.

