Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
Published on: April 29, 2014
Accuracy of Intraoral Scanner for Recording Completely Edentulous Arches-A Systematic Review
Gunjan Srivastava1, Subrat Kumar Padhiary2, Neeta Mohanty3
1Department of Prosthodontics, Institute of Dental Sciences, Siksha 'O' Anusandhan, Deemed To Be University, Bhubaneswar 751003, Odisha, India.
Abstract:
Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose of this study is to systematically review studies (both clinical and in vitro) and determine whether intraoral scanners have clinically acceptable accuracy when recording completely edentulous arches for the fabrication of removable complete dentures. An electronic search in medical databases like PubMed, Scopus, and Web of Science (WOS), using a combination of relevant keywords, retrieved 334 articles. After full-text evaluation, twelve articles fulfilled the inclusion criteria for this review (eight clinical studies and four in vitro studies). A quality analysis of the included studies was carried out using the QUADAS-2 tool. The accuracy values varied between different intraoral scanners. Different regions of the edentulous arches showed differences in trueness and precision values in both in vitro and clinical studies. Peripheral borders, the inner seal, and poorly traceable structures like the soft palate showed maximum discrepancies. The accuracy of intraoral scanners in recording clear anatomic landmarks like hard tissues with attached mucosa was comparable to conventional edentulous arch impressions. However, higher discrepancies were recorded when digitizing mobile and poorly traceable structures. Intraoral scanners can be used to digitize denture-bearing areas, but the interpretation of the peripheral border and the soft palate should be carefully carried out.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.