Related Experiment Video
Updated: Jul 12, 2025

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
Removal of Arsenate by Fixed-Bed Columns Using Chitosan-Magnetite Hydrogel Beads and Chitosan Hydrogel Beads: Effect
Eduardo Mendizabal1, Nely Ríos-Donato1, Carlos Federico Jasso-Gastinel2
1Chemistry Department, CUCEI, University of Guadalajara, Blvd. Gral. Marcelino García Barragán 1421, Guadalajara 44430, Jalisco, Mexico.
Abstract:
Fixed-bed columns packed with chitosan-magnetite (ChM) hydrogel and chitosan (Ch) hydrogel were used for the removal of arsenate ions from aqueous solutions at a pH of 7.0. The effect of flow rate (13, 20, and 25 mL/h), height of the columns (13 and 33 cm), and initial arsenate concentration (2, 5 and 10 mg/L) on the column's efficiency for the removal of As(V) is reported. The maximum adsorption capacity (qb), obtained before the allowed concentration of contaminant is exceeded, the adsorption capacity (qe) when the column is exhausted, and the mass transfer zone were determined. With this information, the efficiency of the column was calculated, which is given by the HL/HLUB ratio. The higher this ratio, the higher the efficiency of the column. The highest efficiency and the highest uptake capacity value at breakthrough point were obtained when using the lower flow rate, lower initial arsenate concentration, and longer bed length. When 33 cm-high columns were fed with a 10 mg As(V)/L solution at 13 mL/h, the maximum uptake capacity values at exhaustion obtained for Ch and ChM were 1.24 and 3.84 mg/g, respectively. A pH increase of the solution at the column's exit was observed and is attributed to the proton transfer from the aqueous solution to the amino and hydroxyl groups of chitosan. The incorporation of magnetite into Ch hydrogels significantly increases their capacity to remove As(V) due to the formation of complexes between arsenic and the magnetite surface. Experimental data were fitted to the Thomas model, the Yoon-Nelson model and the Bohart-Adams model using non-linear regression analysis.
More Related Videos
Related Concept Videos
Principles Of Column Chromatography
Extraction: Advanced Methods
Ion Exchange
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...

