Related Experiment Video
Updated: Jul 12, 2025

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Distal Versus Proximal Radial Artery Access for Cardiac Catheterization: 30-Day Outcomes of the DIPRA Study
Karim Al-Azizi1, Ghadi Moubarak2, Chadi Dib1
1Department of Cardiology Baylor Scott and White The Heart Hospital Plano TX.
Insights
Distal radial artery (dRA) access for cardiac catheterization is safe and preserves the artery, showing no increased risk of hand dysfunction compared to proximal radial artery (pRA) access. This approach offers a viable alternative for procedures.
Area of Science:
- Cardiology
- Vascular Access
- Interventional Cardiology
Background:
- Proximal radial artery (pRA) access for cardiac catheterization can compromise future use of the artery due to occlusion.
- Distal radial artery (dRA) access in the anatomical snuffbox aims to preserve radial artery patency.
- The safety and impact on hand function of dRA access remain largely unknown.
Purpose of the Study:
- To compare the safety and efficacy of distal radial artery (dRA) versus proximal radial artery (pRA) access for cardiac catheterization.
- To evaluate the impact of dRA versus pRA access on hand function at 30 days post-procedure.
Main Methods:
- The DIPRA study randomized 300 patients to cardiac catheterization via dRA or pRA (1:1 ratio).
- Hand function was assessed using the QuickDASH questionnaire, hand-grip, and pinch-grip tests at baseline and 30 days.
- Secondary endpoints included access feasibility and complication rates.
Main Results:
- No significant difference in the composite hand function outcome between dRA and pRA groups.
- Similar rates of access site bleeding (dRA 0% vs. pRA 1.4%).
- Radial artery occlusion occurred in 2 pRA cases, none in dRA; dRA access failed in 6 patients versus 2 in pRA.
Conclusions:
- Distal radial artery (dRA) access is a safe strategy for cardiac catheterization with a low complication rate.
- dRA access does not increase the risk of hand dysfunction at 30 days compared to pRA access.
- dRA access preserves the radial artery, potentially allowing for future interventions.
Abstract:
Background Proximal radial artery (pRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (dRA) access in the anatomical snuffbox preserves the radial artery, but safety and potential detrimental effects on hand function are unknown. Methods and Results In the DIPRA (Distal Versus Proximal Radial Artery Access for Cardiac Catheterization and Intervention) study, a single-center trial, 300 patients were randomized 1:1 to cardiac catheterization through dRA or pRA. The primary end point of change in hand function from baseline to 30 days was a composite of the QuickDASH (Quick Disabilities of the Arm, Shoulder and Hand) questionnaire, hand-grip test, and thumb forefinger pinch test. Secondary end points included access feasibility and complications; 254 of 300 patients completed follow-up at 30 days; of these, 128 were randomized to dRA and 126 to pRA with balanced demographic and procedural characteristics. Both groups had similar rates of access site bleeding (dRA 0% versus pRA 1.4%; P=0.25). Six patients with dRA failed access compared with 2 patients with pRA. Radial artery occlusion occurred in 2 pRA versus none in dRA. There were no significant differences in change in hand function, median hand-grip (dRA 0 [-3.2, 3.3] versus pRA 0.7 [-2.3, 3.3] kg; P=0.21), pinch-grip (dRA -0.3 [-1.2, 0.5] versus pRA 0 [-0.9, 0.9] kg; P=0.09), and QuickDASH (dRA 0 [-4.6, 2.3] versus pRA 0 [-4.6, 2.3] points, P=0.96). There was no significant difference in the composite of hand function between pRA and dRA. Conclusions dRA is a safe strategy for cardiac catheterization with a low complication rate. Compared with pRA, there is no increased risk of hand dysfunction at 30 days. Registration URL: https://www.ClinicalTrials.gov. Unique identifier: NCT04318990.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Peripheral Artery Disease III: Interprofessional Care
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Cardiac Catheterization I: Pre-Procedure Overview