Related Experiment Video
Updated: Jul 12, 2025

Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Association of Shock Index with Echocardiographic Parameters in Cardiac Intensive Care Unit
Meir Tabi1, Mitchell Padkins2, Barry Burstein3
1Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, United States of America; Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel.
Background:
A high shock index (SI), the ratio of heart rate (HR) to systolic blood pressure (SBP), has been associated with unfavorable outcomes. We sought to determine the hemodynamic underpinnings of an elevated SI using 2-D and doppler Transthoracic Echocardiography (TTE) in unselected cardiac intensive care unit (CICU) patients.
Methods:
We included Mayo Clinic CICU admissions from 2007 to 2018 who were in sinus rhythm at the time of TTE. The SI was calculated using HR and SBP at the time of TTE. Patients were grouped according to SI: <0.7, 4012 (64%); 0.7-0.99, 1764 (28%); and ≥ 1.0, 513 (8%). Pearson's correlation coefficient was used to assess associations between continuous variables.
Results:
We included 6289 unique CICU patients, 58% of whom had acute coronary syndrome. The median age was 67.9 years old and 37.8% were females. The mean SI was 0.67 BPM/mmHg. As the SI increased, markers of left ventricular (LV) systolic function and forward flow decreased, including left ventricular ejection fraction (LVEF), fractional shortening, left ventricular outflow tract (LVOT) velocity time integral (VTI), stroke volume, LV stroke work index, and cardiac power output. Biventricular filling pressures increased, and markers of right ventricular function worsened with rising SI. Most TTE measurements reflecting LV function and forward flow were inversely correlated with SI, including LV stroke work index (r = -0.59) and LVOT VTI (r = -0.41), as were both systemic vascular resistance index (r = -0.43) and LVEF (r = -0.23).
Conclusion:
CICU patients with elevated SI have worse biventricular function and systemic hemodynamics, particularly decreased stroke volume and related calculated TTE parameters. The SI is an easily available marker that can be used to identify CICU patients with unfavorable hemodynamics who may require further assessment.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies

