Related Experiment Video
Updated: Jul 12, 2025

Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Reprocessing semicritical items: An overview and an update on the shift from HLD to sterilization for endoscopes
William A Rutala1, David J Weber2
1Statewide Program for Infection Control and Epidemiology, University of North Carolina Hospitals, Chapel Hill, NC; Division of Infectious Diseases, UNC School of Medicine, Chapel Hill, NC.
Background:
Semicritical medical devices are defined as items that come into contact with mucous membranes or nonintact skin (e.g., gastrointestinal endoscopes, endocavitary probes). Such medical devices require minimally high-level disinfection.
Methods:
Analyze the methods used to reprocess semicritical medical devices and identify methods and new technologies to reduce the risk of infection.
Results:
The reprocessing methods for semicritical medical devices is described as well as a shift from high-level disinfection to sterilization for lumened endoscopes.
Conclusions:
Strict adherence to current guidelines and transition to sterilization for endoscopes is required as more outbreaks have been linked to inadequately disinfected endoscopes and other semicritical items than any other reusable medical devices.
More Related Videos
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
10:29Semi-automatic PD-L1 Characterization and Enumeration of Circulating Tumor Cells from Non-small Cell Lung Cancer Patients by Immunofluorescence
Published on: August 14, 2019
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Hand hygiene
Hand washing...
Handwashing III: During the Procedure and Post-Procedure Steps