Related Experiment Video
Updated: Aug 6, 2026

Thin-layer Chromatographic TLC Separations and Bioassays of Plant Extracts to Identify Antimicrobial Compounds
Published on: March 27, 2014
Greenness assessment of two chromatographic methods developed for the determination of Mupirocin in two binary
Maha M Galal1, Shaaban A Abdullah2, Ola Y Mohamed2
1Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini street, Cairo, 11562, Egypt. maha.galal@pharma.cu.edu.eg.
Abstract:
Two simple, accurate and precise chromatographic methods have been developed and validated for estimating Mupirocin (MUP) in two binary mixtures. Mixture (1); with Fluticasone propionate (FLU) together with two of their impurities, namely; Pseudomonic acid-D (Pseud-D) and Fluticasone impurity C (FIC). Mixture (2); with Mometasone furoate (MF) along with Pseud-D impurity. High performance thin layer chromatography (HPTLC-densitometry) and high performance liquid chromatography (RP-HPLC) were the two proposed methods. In the HPTLC method, good separation of both mixtures was achieved by using HPTLC plates pre-coated with silica gel 60 F254 as stationary phase and the mobile phase consisted of toluene: chloroform: ethanol at a ratio of (5: 4: 2, by volume). The detection was carried out at 220 nm for MUP and 254 nm for FLU, MF, Pseud-D and FIC. In the HPLC method, chromatographic separation was carried out using Agilent Eclipse XDB (250 mm×4.6 mm, 5 μm) C18 column. For mixture (1), a mobile phase of methanol: sodium di-hydrogen phosphate (pH 3.0) was applied in stepwise gradient elution starting at ratios of (50: 50, v/v) and then switching to (80: 20, v/v) after 7 min at a flow rate of 1 mL.min- 1. Detection was performed using diode array detector at 220 nm for MUP and Pseud-D and 240 nm for FLU and FIC. For mixture (2), the same mobile phase was used, but in isocratic elution in the ratio (80: 20, v/v) at flow rate of 1 mL.min- 1 and detection at 220 nm for MUP and Pseud-D and 248 nm for MF. The two methods successfully separated the cited drugs and were used to determine the drugs in pure form as well as pharmaceutical dosage forms. Validation was done as per International Council on Harmonization guidelines. Furthermore, the greenness of the proposed methods compared to the reported method, was evaluated as per the National Environmental Method Index, analytical Eco scale, Green Analytical Procedure Index and Analytical Greenness metric approaches.
More Related Videos
08:31Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022