Objectives:
High-quality randomised controlled trials (RCT) to support the use of Fibrin Sealants (FS) in neck dissection (ND) are lacking. The DEFeND trial assessed critical pilot/feasibility questions and signals from clinical outcomes to inform a future definitive trial.
Patients And Methods:
The study design piloted was a blinded surgical RCT. All participants underwent unilateral ND for head and neck cancer. Interventional arm: ND with application of FS.
Control Arm:
ND alone. Feasibility outcomes included recruitment, effectiveness of blinding, protocol adherence and evaluating administrative processes. Clinical outcomes included surgical complications (primary outcome), drainage volume, time to drain removal, length of hospital stay, pain and the Neck Dissection Impairment Index.
Results:
Recruitment completed ahead of time. Fifty-three patients were recruited, and 48 were randomised at a rate of 5.3 patients/month. Blinding of patients, research nurses and outcome assessors was effective. Two protocol deviations occurred. Two patients were lost to follow-up. The mean (SD) Comprehensive Complication Index in the interventional arm was 6.5 (12.8), and it was 9.9 (14.2) in the control arm. The median (IQR) time to drain removal (days) was shorter in the interventional arm (2.67 (2.42, 3.58) vs. 3.40 (2.50, 4.27)). However, this did not translate to a clinically significant reduction in median (IQR) length of hospital stay in days (intervention: 3.48 (2.64, 4.54), control: 3.74 (3.11, 4.62)).
Conclusion:
The proposed trial design was effective, and a definitive surgical trial is feasible. Whilst there was a tendency for FS to improve clinical outcomes, the effect size did not reach clinical or statistical significance. (ISRCTN99181100).
More Related Videos
03:24Author Spotlight: Development and Application of a Novel Suture Technique for Annular Fibrosus Repair in Percutaneous Transforaminal Endoscopic Discectomy
Published on: January 26, 2024
05:30Surgical Approach and Complications of Stand-alone Lateral Trans-Psoas Interbody Fusion
Published on: February 14, 2025
Related Concept Videos
Aneurysm III: Interprofessional Care
Clot Retraction and Fibrinolysis