Compressive Performance of Longitudinal Steel-FRP Composite Bars in Concrete Cylinders Confined by Different Type of
Maojun Duan1, Yu Tang1, Yusheng Wang1
1College of Civil Engineering, Nanjing Forestry University, Nanjing 210037, China.
Abstract:
This paper presents an experimental study on the compressive performance of longitudinal steel-fiber-reinforced polymer composite bars (SFCBs) in concrete cylinders confined by different type of fiber-reinforced polymer (FRP) composites. Three types of concrete cylinders reinforced with (or without) longitudinal SFCBs and different transverse FRP confinements were tested under monotonic compression. The results showed that the post-yield stiffness of SFCBs is higher when confined with high elastic modulus carbon fiber-reinforced polymer (CFRP) composite than with low elastic modulus basalt fiber-reinforced polymer (BFRP) composite. Decreasing confinement spacing did not significantly improve the compressive strength of SFCBs in concrete cylinders. The compressive failure strain of SFCBs could possibly reach 88% of its tensile peak strain in concrete cylinders confined by CFRP sheets, which is significantly higher than the value (around 50%) in previous studies. Existing design equations, which applied a strength reduction factor or a maximum compressive strain of concrete to consider the compressive contributions of SFCBs in concrete members, underestimate the load-carrying capacity of SFCB-reinforced concrete cylinders. The design equation that considers the actual compressive stress of SFCBs gives the most accurate prediction; however, its applicability and accuracy need to be verified with more experimental data.
More Related Videos
06:21Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Fiber Reinforced Concrete
Reinforcements in Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Relation Between Tensile Strength and Compressive Strength of Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...