Related Experiment Video
Updated: Jul 12, 2025

Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Using Distributed Temperature Sensing for Long-Term Monitoring of Pockmark Activity in the Gulf of Patras (Greece):
Elias Fakiris1, George Papatheodorou1, Dimitris Christodoulou1
1Laboratory of Marine Geology and Physical Oceanography (Oceanus-Lab), Department of Geology, University of Patras, 26504 Patras, Greece.
Abstract:
Patras Gulf pockmark field (Western Greece) is a tectonically controlled field that has been activated at least twice by strong earthquakes (M5.4, 14 July 1993 and M6.4, 8 June 2008), and episodic gas seepages have been recorded in the past using geophysical means. A distributed temperature sensor (DTS) system was deployed inside a shallow pockmark and along an active fault at the northern end of the field. This ongoing experiment represents the first long-term monitoring ever conducted on gas-bearing pockmarks and active faults by the DTS system. For now, we have acquired and analyzed data regarding about 1.56 years. One of the primary objectives of this study is to establish methodological queues for data processing and analysis, including spectral analysis and incomplete data treatment techniques, to be standardized for use in further stages of the experiment. Spectral analysis was proven capable of separating the temperature footprint of background environmental components, such as sea-atmosphere heat flux, tides, and winds/waves, from high-frequency temperature residuals. Those residuals represent unusual events that might be correlated to seismicity. Monitoring the causal relationship between seismic activity and seabed water temperature changes in the field was thus attempted. No significant local earthquakes occurred during the monitoring period. Although the relation between seismicity and irregular seabed water temperature events was not systematic, we postulate that four thermal events have a causative link with the local seismicity. The DTS system constitutes a low-cost monitoring system, and the promising preliminary results of this experiment suggest that it is worth testing for a longer period.
More Related Videos
09:48Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
07:59A Strain Gauge Monitor SGM for Continuous Valve Gape Measurements in Bivalve Molluscs in Response to Laboratory Induced Diel-cycling Hypoxia and pH
Published on: August 1, 2018
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...