Analysis of the capsular bend in posterior capsular opacification using anterior segment optical coherence tomography
1Department of Ophthalmology, Faculty of Medicine (for Girls), Al-Azhar University, Cairo, Egypt. asmagamal14@gmail.com.
Purpose:
To investigate the link between the capsular bend and the morphological types and characteristics of posterior capsular opacification (PCO) using anterior segment optical coherence tomography.
Methods:
Thirty eyes with PCO were examined, and three types of PCO were identified: pearl, fibrosis, and mixed. We assessed anterior capsular overlap, intraocular lens-capsule adhesion, and capsular bending. In addition to measuring the intraocular lens-posterior capsule distance and capsule bending angle (CBA), the PCO parameters (area, density, and score at 6-, 5-, and 3-mm intraocular lens optic regions) were recorded. The associations between capsular bend and PCO type and characteristics were investigated. A control group of 12 eyes without PCO was used to compare the study variables.
Results:
With p values greater than 0.001, there was a statistically significant difference in the mean PCO area and score at the 6-, 5-, and 3-mm optic zones in different PCO types, with the pearl type having the highest value, followed by the mixed type, and finally the fibrosis type. The PCO group had a significantly higher mean CBA than the control group (P = 0.001). CBA was positively related to intraocular lens-posterior capsule distance, PCO area, and PCO score at the 6-, 5-, and 3-mm zones (P = 0.001). The receiver operating characteristic curve's cut-off point for CBA was 96.85° when comparing PCO cases to controls. Partial overlap and incomplete adhesion were statistically more common in the PCO eyes than in the control (P = 0.001, 0.003, respectively).
Conclusion:
PCO types and CBA have a strong relationship with PCO score and intraocular lens-posterior capsule space. In PCO's eyes, CBA has a cut-off value of 96.85°.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...