Related Experiment Video
Updated: Jul 12, 2025

Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
Experimental Investigation of X-Ray Radiation Shielding and Radiological Properties for Various Natural Composites
Sonal Varshney1,2, Lalit Kumar3, Umesh Kumar Dwivedi1
1Department of Physics, Amity School of Applied Sciences, Amity University Rajasthan, Jaipur, India.
Background:
Shielding from radiation and plan dose verification is vital during the potential applications in industrial and medical applications. A number of natural composites have been investigated for protecting against high-energy X-ray shielding.
Objective:
The aim is to learn about how natural composites behave under various X-ray energies at STP.
Material And Methods:
The radiological parameters of wood samples were determined using computed tomography imaging, specifically relative electron density (RED), Hounsfield units (HUs), and mass density (MD). Percentage attenuation was measured using a semiflux ionization chamber incorporated with a brass build-up cap and an ionization chamber placed at the beam Isocenter for a different type of natural composite. Measurements are being carried out on a Linear accelerator at an SSD of 110 cm with different collimator sizes.
Results:
Measured values of HUs, RED, and MD were -232 ± 40, 0.738 ± 0.039, 0.768 ± 0.024 g/cc,-368 ± 41, 0.662 ± 0.047, 0.632 ± 0.024 g/cc, -334 ± 44, 0.639 ± 0.042, 0.666 ± 0.026 g/cc, -370±61, 0.604±0.059, 0.63± 0.036 g/cc, -433±39, 0.543±0.038, 0.608 ± 0.035 g/cc, -382±54, 0.5±0.052, 0.618 ± 0.0316 g/cc, -292±68, 0.680±0.066, 0.708 ± 0.039 g/cc, -298±27, 0.680±0.0229, 0.702± 0.131 g/cc, for Acacia Nilotica, Mangifera Indica, Azadirachta Indica, Tectona Grandis L, Ficus Religiosa, Tecomella Undulata, Sesamum Indicum, Pinus respectively.
Conclusion:
Measurements show that attenuation is affected by the energy of incident photons, collimator opening, and the type of density of the wood. Various radiological parameters were determined for wood samples that can be utilized to create inhomogeneous phantoms in dosimetry. The largest attenuation is found in Acacia Nilotica and Sesamum Indicum, while the lowest attenuation is found in Ficus religiosa.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
Related Concept Videos
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Radiological Investigation I: X-ray and CT
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...