Related Experiment Video
Updated: Jul 12, 2025

Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
Published on: March 21, 2021
D3-creatine dilution, computed tomography and dual-energy X-ray absorptiometry for assessing myopenia and physical
En Cheng1,2, Bette J Caan2, Peggy M Cawthon3,4
1Department of Epidemiology and Population Health, Albert Einstein College of Medicine, Bronx, New York, USA.
Background:
Low skeletal muscle mass (myopenia) is common in cancer populations and is associated with functional decline and mortality, but prior oncology studies did not assess total body skeletal muscle mass. Instead, they measured surrogates such as cross-sectional area (CSA) of skeletal muscle at L3 from computed tomography (CT) or appendicular lean mass (ALM) from dual-energy X-ray absorptiometry (DXA). D3-creatine (D3Cr) dilution is a non-invasive method to assess total body skeletal muscle mass, which has been examined in a variety of populations but not in cancer. To compare the associations of D3Cr muscle mass, CT CSA, and DXA ALM with myopenia and physical function, we conducted a cross-sectional study among 119 patients with colon cancer (2018-2022).
Methods:
For each technique (D3Cr, CT and DXA), myopenia was defined as the lowest sex-specific quartile of its measurement. Physical function was measured by the short physical performance battery and grip strength. We calculated Pearson correlations (r) among three techniques, computed Cohen's kappa coefficients (κ) to assess the agreement of myopenia, and estimated Pearson correlations (r) of three techniques with physical function. All analyses were sex-specific.
Results:
Sixty-one (51.3%) participants were male, the mean (standard deviation) age was 56.6 (12.9) years, and most (68.9%) had high physical function (short physical performance battery: ≥11 points). Correlations and myopenia agreement among three techniques were greater in men than women; for example, regarding D3Cr muscle mass versus CT CSA, r was 0.73 (P < 0.001) for men versus 0.45 (P < 0.001) for women, and κ was 0.82 (95% CI: 0.65, 0.99) for men versus 0.24 (95% CI: -0.08, 0.52) for women. Among men, higher D3Cr muscle mass was significantly correlated with faster gait speed (r = 0.43, P < 0.01) and stronger grip strength (r = 0.32, P < 0.05); similar correlations were observed for CT CSA and DXA ALM. However, among women, no measure of muscle or lean mass was significantly associated with physical function.
Conclusions:
This is the first study using D3-creatine dilution method to assess muscle mass in a cancer population. Regardless of the techniques used for muscle or lean mass assessment, we observed stronger correlations, greater myopenia agreement, and more significant associations with physical function in men with colon cancer than women. D3Cr, CT and DXA are not interchangeable methods for assessing myopenia and physical function, especially in women with colon cancer. Future studies should consider relative advantages of these techniques and examine the D3-creatine dilution method in other cancer types.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

