Related Experiment Video
Updated: Jul 12, 2025

A Do-it-yourself System for Scheduled Feeding of Laboratory Rodents in Their Home Cage
Published on: June 6, 2025
Advanced Hybrid Closed-Loop System Achieves and Maintains Recommended Time in Range Levels for Up To 2 Years:
Giuseppe Lepore1, Nicolò Diego Borella1, Giona Castagna1,2
1Unit of Endocrine Diseases and Diabetology, Department of Medicine, ASST Papa Giovanni XXIII, Bergamo, Italy.
Abstract:
Aim: To evaluate the long-term efficacy, up to 2 years, of an advanced hybrid closed-loop (AHCL) system and to assess predictors of best results of the therapy. Methods: We retrospectively evaluated 296 adults with type 1 diabetes mellitus [mean age 42.8 ± 16.5 years, men 42.9%, duration of diabetes 22.5 ± 12.8 years, body mass index 24.9 ± 4.7 kg/m2, baseline glycated hemoglobin (HbA1c) 63.4 ± 12.2 mmol/mol (8.0 ± 1.1%) ] who used the MiniMed™ 780G system. Demographic and clinical data were recorded. Continuous glucose monitoring (CGM)-derived metrics and insulin requirement were analyzed from the 4 weeks before and from every quarter after the switch to the AHCL system. Results: In the first quarter of AHCL treatment, all CGM metrics improved. Time in range (TIR) increased from 58.1 ± 17.5% to 70.3 ± 9.5% (P < 0.0001). The improvement lasted for up to 2 years of observation regardless of previous insulin therapies. Throughout the period of observation, 53.4% of participants achieved mean TIR >70%, 92.6% mean time below range <4%, and 46% mean glucose management indicator <53 mmol/mol (7.0%). At univariable logistic regression older age, lower baseline HbA1c and insulin requirement were associated with mean TIR >70%. At multivariable analysis, lower HbA1c remained independently associated with a better glycemic control. However, mean TIR increased more in participants with a higher baseline HbA1c. Conclusions: Switching to an AHCL leads to a rapid improvement in glycemic control lasting for up to 24 months along with a low risk for hypoglycemia, confirming the safety of the system. Lower baseline HbA1c was the main predictor of better efficacy of therapy, although higher baseline HbA1c was associated with the greatest improvement in mean TIR.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Holter Monitor: 24-Hour Monitoring
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Control Systems
At the heart...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...