Related Experiment Video
Updated: Jul 12, 2025

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Quantifying Platinum and Palladium in Solid Ore Using Laser-Induced Breakdown Spectroscopy Assisted by the
Ismail Elhamdaoui1, Samira Selmani1, Mohamad Sabsabi2
1Institut National de la Recherche Scientifque, Centre Énergie Matériaux Télécommunications, Varennes, Quebec, Canada.
Abstract:
The laser-induced breakdown spectroscopy assisted by laser-induced fluorescence (LIBS-LIF) in a two-step process was used to measure the concentration of platinum (Pt) and palladium (Pd) by surface analysis of a solid ore core from the Lac des Iles mine followed by analysis of the same core that was pulverized and compacted. This work focuses mainly on the measurement of Pt since the case of Pd has been extensively discussed in previous work. The excitation of Pt is performed at 235.71 nm with fluorescence emission observed near 269.84 nm. Calibration was performed with synthetic samples prepared from the same ore as the samples studied and the calibration curve shows good linearity in Pt content over several orders of magnitude. A limit of detection (LOD) of approximately 0.15 parts per million (ppm) over an average of 200 laser shots was demonstrated. In contrast, conventional LIBS provides a LOD of about 21 ppm over an average of 200 laser shots due to low signal-to-noise ratio and spectral interference from other elements and does not meet the requirements for estimating the average Pt concentration in the ore. The Pt concentrations obtained using LIBS-LIF on solid ore are generally in good agreement with those obtained in its pulverized and compacted form, as well as with laboratory measurements made by conventional chemical methods. However, the comparison of the results obtained for Pd using LIBS-LIF with the laboratory showed a less satisfactory agreement, probably due to its more inhomogeneous distribution in the ore.
More Related Videos
10:17Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Flame Photometry: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Overview
Flame Photometry: Overview