Pulse Wave Velocity of 8.2 m/s as a Threshold Associated with Cardiovascular Target Organ Damage Presence
Sayuri Inuzuka1, Priscila Valverde de Oliveria Vitorino2, Adriana Sebba Barroso1
1Universidade Federal de Goiás - Liga de Hipertensão Arterial, Goiânia, GO - Brasil.
Background:
Previous studies have established normal and reference values for Pulse Wave Velocity (PWV). However, the PWV value that has the strongest association with cardiovascular biomarkers remains poorly understood.
Objective:
This study aimed to determine the PWV value more likely to be associated with left ventricular hypertrophy (LVH), increased intima-media thickness (IMT), and presence of carotid plaques in patients with hypertension.
Methods:
This cross-sectional study included 119 patients. Analysis of receiver operating characteristic (ROC) curves was performed for each cardiovascular biomarker. Statistical significance was set at p < 0.05.
Results:
According to the ROC curve analysis, the PWV values were 8.1 m/s, 8.2 m/s, and 8.7 for the LVH, IMT, and presence of carotid plaques, respectively. A PWV value of 8.2 m/s was identified as the best parameter to determine the three TOD biomarkers. PWV above 8.2 m/s was associated with increased CIMT (p = 0.004) and the presence of carotid plaques (p = 0.003) and LVH (p<0.001). PWV above 8.2 showed greater sensitivity for increased CIMT (AUC = 0.678, sensitivity = 62.2), LVH (AUC = 0.717, sensitivity = 87.2), and the presence of plaques (AUC = 0.649, sensitivity = 74.51) in the ROC curve analysis.
Conclusion:
The PWV value 8.2 m/s was more sensitive in early identifying the existence of cardiovascular biomarkers of TOD.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Blood Pressure
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: