Related Experiment Video
Updated: Jul 12, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
The variability of CT scan protocols for total hip arthroplasty: a call for harmonisation
Angelika Ramesh1,2, Anna Di Laura1,2, Johann Henckel2
1Department of Mechanical Engineering, University College London, United Kingdom.
Abstract:
CT is the principal imaging modality used for the pre-operative 3D planning and assessment of total hip arthroplasty (THA). The image quality offered by CT has a radiation penalty to the patient. Higher than necessary radiation exposure is of particular concern when imaging young patients and women of childbearing age, due to the greater risk of radiation-induced cancer in this group. A harmonised low-dose CT protocol is needed, evidenced by the huge variability in the 17 protocols reviewed. The majority of the protocols were incomplete, leading to uncertainty among radiographers when performing the scans. Only three protocols (20%) were optimised for both 'field of view' and image acquisition parameters. 10 protocols (60%) were optimised for 'field of view' only. These protocols included imaging of the relevant landmarks in the bony pelvis in addition to the knees - the reference for femoral anteversion. CT parameters, including the scanner kilovoltage (kV), milliamperage-time product (mAs) and slice thickness, must be optimised with a 'field of view' that includes the relevant bony landmarks. The recommended kV and mAs values were very wide ranging from 100 to 150 and from 100 to 250, respectively. The large variability that exists amongst the CT protocols illustrates the need for a more consistent low-dose CT protocol for the planning of THA. This must provide an optimal balance between image quality and radiation dose to the patient. Current CT scanners do not allow for measurements of functional pelvic orientation and additional upright imaging modalities are needed to augment them.
More Related Videos
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...