Related Experiment Video
Updated: Jul 12, 2025

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Evaluation of torsional strength and torque presentation of coated rectangular stainless steel archwires, an in vitro
Parisa Salehi1, Shabnam Ajami1, Nazanin Berahman1
1Orthodontics Research Center, Department of Orthodontics, School of Dentistry, Shiraz University of Medical Sciences, Qom-aabad Street, Ghasrdasht Avenue, Shiraz, Iran.
Objectives:
An in vitro experimental study was performed to evaluate the torsional strength and torque released by esthetic coated archwires.
Materials And Methods:
A total of 52 coated (study group) and 52 stainless steel (control group) rectangular archwires from two manufacturers (brand I: Gestenco International AB, Gothenburg, Sweden and brand II: Ortho Technology, Lutz, FL, USA) in two sizes (0.019 × 0.025 and 0.017 × 0.0250-inch) were evaluated. The straight parts on both ends of each preformed archwire were cut in 30 mm segments. A specially designed experimental device was attached to the universal testing machine (Model Z020, Zwick Roell, Ulm, Germany) to measure torsional strength and to calculate the clinically significant torque interval. The groups were compared based on their brand, presence of coating and size using three-way analysis of variance (ANOVA) test at a significance level of 5%.
Results:
The results revealed that coating of the wires of brand 1 resulted in a significant reduction of torsional strength in both wire sizes (P-value = 0.0001). For the wires of brand 2, coating of the 0.017 × 0.025-in wire resulted in a significant reduction in torsional strength. However, for the 0.019 × 0.025 in wire size, the presence of coating significantly increased the torsional strength (P-value = 0.0001). Coating did not affect the measured clinical torque interval of the analyzed wires when a torque between 5 and 20 Nmm was applied (P-value = 0.062).
Conclusions:
Mechanical behavior of coated archwires depends mainly on the thickness of their inner core alloy. Reduction in the diameter of the inner alloy resulted in reduced torsional strength. Despite lower mean torsional strength, in the settings of this study, coated and conventional wires demonstrated comparable torque angles if loaded in the typical range of activation.
Related Concept Videos
Torsion of Noncircular Members
Thin-Walled Hollow Shafts
Stress Concentrations in Circular Shafts
Deformation in a Circular Shaft
Residual Stresses in Circular Shafts
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...