Related Experiment Video
Updated: Jul 12, 2025

Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Inferior vena cava ultrasound and other techniques for assessment of intravascular and extravascular volume: an
Elaine M Kaptein1, Matthew J Kaptein1,2
1Departments of Medicine, Divisions of Nephrology, University of Southern California, Los Angeles, CA, USA.
Abstract:
Goals of volume management are to accurately assess intravascular and extravascular volume and predict response to volume administration, vasopressor support or volume removal. Data are reviewed that support the following: (i) Dynamic parameters reliably guide volume administration and may improve clinical outcomes compared with static parameters, but some are invasive or only validated with mechanical ventilation without spontaneous breathing. (ii) Ultrasound visualization of inferior vena cava (IVC) diameter variations with respiration reliably assesses intravascular volume and predicts volume responsiveness. (iii) Although physiology of IVC respiratory variations differs with mechanical ventilation and spontaneous breathing, the IVC collapsibility index (CI) and distensibility index are interconvertible. (iv) Prediction of volume responsiveness by IVC CI is comparable for mechanical ventilation and spontaneous breathing patients. (v) Respiratory variations of subclavian/proximal axillary and internal jugular veins by ultrasound are alternative sites, with comparable reliability. (vi) Data support clinical applicability of IVC CI to predict hypotension with anesthesia, guide ultrafiltration goals, predict dry weight, predict intra-dialytic hypotension and assess acute decompensated heart failure. (vii) IVC ultrasound may complement ultrasound of heart and lungs, and abdominal organs for venous congestion, for assessing and managing volume overload and deresuscitation, renal failure and shock. (viii) IVC ultrasound has limitations including inadequate visualization. Ultrasound data should always be interpreted in clinical context. Additional studies are required to further assess and validate the role of bedside ultrasonography in clinical care.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies VII: Vascular Imaging
Imaging Studies II: Ultrasonography

