Related Experiment Video
Updated: Jul 3, 2026

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Use of simulated data to explore the application of optical coherence tomography for classifying middle-ear
Marzieh Golabbakhsh1, W Robert J Funnell1
1Department of BioMedical Engineering, McGill University, Montréal, Québec, Canada.
Abstract:
Optical coherence tomography (OCT) vibrometry is a non-invasive tool for functional imaging of the middle ear. It provides spatially resolved vibrational responses and also anatomical images of the same ear. Our objective here was to explore the potential of OCT vibration measurements at the incus, as well as at the umbo, to distinguish among middle-ear disorders. Our approach was to build finite-element models of normal and pathological ears, generate large amounts of synthetic data, and then classify the simulated data into normal and pathological groups using a decision tree based on features extracted from simulated vibration magnitudes. We could distinguish between normal ears and ears with incudomallear joint (IMJ) disarticulation or stapes fixation, with the sensitivity and specificity both being 1.0; distinguish between stapes fixation and IMJ disarticulation with a sensitivity of 0.900 and a specificity of 0.889; and distinguish ears with ISJ disarticulation from normal ears with a sensitivity of 0.784 and a specificity of 0.872. Less extreme pathologies were also simulated. The results suggest that the vibration measurements within the middle ear that can be provided by OCT (e.g., at the incus) may be very valuable for diagnosis.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
03:42High-Speed Human Temporal Bone Sectioning for the Assessment of COVID-19-Associated Middle Ear Pathology
Published on: May 18, 2022
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Anatomy of the Ear
Imaging Studies III: Computed Tomography