Related Experiment Video
Updated: Jul 12, 2025

An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
Experiences of Patients With Chronic Obstructive Pulmonary Disease Using the Apple Watch Series 6 Versus the
Yuxin Liu1, Antonia Arnaert1, Daniel da Costa1
1Ingram School of Nursing, McGill University, Montreal, QC, Canada.
Background:
Amid the rise in mobile health, the Apple Watch now has the capability to measure peripheral blood oxygen saturation (SpO2). Although the company indicated that the Watch is not a medical device, evidence suggests that SpO2 measurements among patients with chronic obstructive pulmonary disease (COPD) are accurate in controlled settings. Yet, to our knowledge, the SpO2 function has not been validated for patients with COPD in naturalistic settings.
Objective:
This qualitative study explored the experiences of patients with COPD using the Apple Watch Series 6 versus a traditional finger pulse oximeter for home SpO2 self-monitoring.
Methods:
We conducted individual semistructured interviews with 8 female and 2 male participants with moderate to severe COPD, and transcripts were qualitatively analyzed. All received a watch to monitor their SpO2 for 5 months.
Results:
Due to respiratory distress, the watch was unable to collect reliable SpO2 measurements, as it requires the patient to remain in a stable position. However, despite the physical limitations and lack of reliable SpO2 values, participants expressed a preference toward the watch. Moreover, participants' health needs and their unique accessibility experiences influenced which device was more appropriate for self-monitoring purposes. Overall, all shared the perceived importance of prioritizing their physical COPD symptoms over device selection to manage their disease.
Conclusions:
Differing results between participant preferences and smartwatch limitations warrant further investigation into the reliability and accuracy of the SpO2 function of the watch and the balance among self-management, medical judgment, and dependence on self-monitoring technology.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: