A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Signal quality assessment of peripheral venous pressure
Neng-Tai Chiu1, Beau Chuang1, Suthawan Anakmeteeprugsa2
1School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Abstract:
Develop a signal quality index (SQI) for the widely available peripheral venous pressure waveform (PVP). We focus on the quality of the cardiac component in PVP. We model PVP by the adaptive non-harmonic model. When the cardiac component in PVP is stronger, the PVP is defined to have a higher quality. This signal quality is quantified by applying the synchrosqueezing transform to decompose the cardiac component out of PVP, and the SQI is defined as a value between 0 and 1. A database collected during the lower body negative pressure experiment is utilized to validate the developed SQI. All signals are labeled into categories of low and high qualities by experts. A support vector machine (SVM) learning model is trained for practical purpose. The developed signal quality index coincide with human experts' labels with the area under the curve 0.95. In a leave-one-subject-out cross validation (LOSOCV), the SQI achieves accuracy 0.89 and F1 0.88, which is consistently higher than other commonly used signal qualities, including entropy, power and mean venous pressure. The trained SVM model trained with SQI, entropy, power and mean venous pressure could achieve an accuracy 0.92 and F1 0.91 under LOSOCV. An exterior validation of SQI achieves accuracy 0.87 and F1 0.92; an exterior validation of the SVM model achieves accuracy 0.95 and F1 0.96. The developed SQI has a convincing potential to help identify high quality PVP segments for further hemodynamic study. This is the first work aiming to quantify the signal quality of the widely applied PVP waveform.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure in the Leg
Preparation:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: