Finite-time contraction stability of a stochastic reaction-diffusion dengue model with impulse and Markov switching

Wei You1, Jie Ren2, Qimin Zhang1

  • 1School of Mathematics and Statistics, Ningxia University, Yinchuan 750021, China.

Related Concept Videos

BIBO stability of continuous and discrete -time systems01:24

BIBO stability of continuous and discrete -time systems

System stability is a fundamental concept in signal processing, often assessed using convolution. For a system to be considered bounded-input bounded-output (BIBO) stable, any bounded input signal must produce a bounded output signal. A bounded input signal is one where the modulus does not exceed a certain constant at any point in time.
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
403
Theories of Dissolution: The Danckwerts' Model and Interfacial Barrier Model01:09

Theories of Dissolution: The Danckwerts' Model and Interfacial Barrier Model

Various dissolution theories provide insight into the factors that influence the dissolution rate. Danckwerts' Model suggests that turbulence, rather than a stagnant layer, characterizes the dissolution medium at the solid-liquid interface. In this model, the agitated solvent contains macroscopic packets that move to the interface via eddy currents, facilitating the absorption and delivery of the drug to the bulk solution. The regular replenishment of solvent packets maintains the...
320
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
189
Second Order systems II01:18

Second Order systems II

In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
115
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...
91
Basic Continuous Time Signals01:22

Basic Continuous Time Signals

Basic continuous-time signals include the unit step function, unit impulse function, and unit ramp function, collectively referred to as singularity functions. Singularity functions are characterized by discontinuities or discontinuous derivatives.
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
216