Paper-Based Supercapacitive Pressure Sensor for Wrist Arterial Pulse Waveform Monitoring
Azmal Huda Chowdhury1, Borzooye Jafarizadeh1, Nezih Pala2
1Department of Mechanical and Materials Engineering, Florida International University, Miami, Florida 33174, United States.
Abstract:
Recent developments in wearable pressure sensors have led to the need for high sensitivity and a broad sensing range to accurately detect various physiological states. However, high sensitivity does not always translate to a wide sensing range, and manufacturing sensors with such high sensitivity is a complex and expensive process. In this study, we present a capacitive pressure sensor based on tissue paper that is simple to produce and cost-effective yet still exhibits high linear sensitivity of 2.9 kPa-1 in the 0-16 kPa range. The linear sensitivity of 1.5 kPa-1 was achieved from 16 to 90 kPa. The sensor also demonstrated a fast response time of 0.2 s, excellent pressure resolution at both low and high pressures, and a sufficient signal-to-noise ratio, making it ideal for detecting wrist arterial pulse waveforms. We were also able to demonstrate the sensor's practicality in real-world applications by cycling it 5000 times and showing its capability to capture pulse waveforms from different arterial locations. These low-cost sensors possess all the intrinsic features necessary for efficient measurement of pulse waveforms, which may facilitate the diagnosis of cardiovascular diseases.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.