Related Experiment Video
Updated: Jul 11, 2025

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Comparison of L1-S1 neuroforaminal dimensions derived from plain film radiography versus computed tomography
Jacob Razzouk1, Davis Carter1, Mei Carter1
1School of Medicine, Loma Linda University, Loma Linda, CA, USA.
Purpose:
To compare measurements of lumbar neuroforaminal dimensions (NFD) derived from plain film radiography (PFR) and computed tomography (CT) of young patients without spinal pathology.
Methods:
We analyzed 213 patients between 18 and 35 years of age without spinal pathology who received PFR and CT within one year of each other. NFD were defined as foraminal height, sagittal anterior-to-posterior width, and area. Statistical analyses assessed correlations and differences between PFR- and CT-derived NFD measurements.
Results:
111 subjects were female and 102 were male. Significant differences between PFR- and CT-derived NFD measurements were observed for all levels L1-S1, with those for foraminal height listed as follows: 4.10 mm at L1-L2, 1.58 mm at L2-L3, 3.23 mm at L3-L4, 4.27 mm at L4-L5, and 1.75 mm at L5-S1. Regarding foraminal area, these differences were 72.20, 73.45, 61.80, 35.38, and 16.18 mm2, respectively. PFR-derived measurements of NFD were larger compared to those derived from CT across all levels (p < .001). Only weak (0 ≤ r ≤ .4) or moderate (.4 ≤ r ≤ .7) correlations were observed between PFR- and CT-derived NFD measurements for all levels from L1-S1.
Conclusion:
This study describes 9585 measurements from L1-S1 of neuroforaminal measurements derived from CT and plain film radiography from a sample of young patients without spinal pathology. Among these patients, plain film measurements of the neuroforamina are larger compared to those derived from CT for all levels from L1-S1. There is poor correlation and reliability between plain film and CT measurements of neuroforaminal dimensions.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies for Cardiovascular System V: CT