Related Experiment Video
Updated: Aug 2, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Whole-tumor apparent diffusion coefficient histogram analysis for preoperative risk stratification in endometrial
Xiaoliang Ma1,2, Limin Xu3, Fenghua Ma4
1Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China.
Objective:
To investigate the application of whole-tumor apparent diffusion coefficient (ADC) histogram metrics for preoperative risk stratification in endometrial endometrioid adenocarcinoma (EEA).
Methods:
Preoperative MRI of 502 EEA patients were retrospectively analyzed. Whole tumor ADC histogram analysis was performed with regions of interest drawn on all tumor slices of diffusion-weighted imaging scans. Risk stratification was based on ESMO-ESTRO-ESP guidelines: low-, intermediate-, high-intermediate-, and high-risk. Univariable analysis was used to compare ADC histogram metrics (tumor volume, minADC, maxADC, and meanADC; 10th, 25th, 50th, 75th, and 90th percentiles of ADC [recorded as P10, P25, P50, P75, and P90 ADC, respectively]; skewness; and kurtosis) between different risk EEAs, and multivariable logistic regression analysis to determine the optimal metric or combined model for risk stratifications. Receiver operating characteristic curve analysis with the area under the curve (AUC) was used for diagnostic performance evaluation.
Results:
A decreasing tendency in multiple ADC values was observed from the low- to high-intermediate-risk EEAs. The (low + intermediate)-risk EEAs and low-risk EEAs had significantly smaller tumor volumes and higher minADCs, meanADCs, P10, P25, P50, P75, and P90 ADCs than the (high-intermediate + high)-risk EEAs and non-low-risk EEAs (all P < 0.05), respectively. The combined models of the (meanADC + volume) and the (P75 ADC + volume) yielded the largest AUCs of 0.775 and 0.780 in identifying the (low + intermediate)- and the low-risk EEAs from the other EEAs, respectively.
Conclusion:
Whole-tumor ADC histogram metrics might be helpful for preoperatively identifying low- and (low + intermediate)-risk EEAs, facilitating personalized therapeutic planning.
More Related Videos
12:41Multiparametric Tumor Organoid Drug Screening Using Widefield Live-Cell Imaging for Bulk and Single-Organoid Analysis
Published on: December 23, 2022
07:46Author Spotlight: Advancing Reproductive Immunology with a Protocol for the Quantitative Evaluation of Endometrial Immune Cells
Published on: October 13, 2023