Related Experiment Video
Updated: Jul 11, 2025

Setting Limits on Supersymmetry Using Simplified Models
Published on: November 15, 2013
Optimized O(α_{s}^{2}) Correction to Exclusive Double-J/ψ Production at B Factories
Wen-Long Sang1, Feng Feng2,3, Yu Jia2,4
1School of Physical Science and Technology, Southwest University, Chongqing 400700, China.
Abstract:
The failure of observing the e^{+}e^{-}→J/ψJ/ψ events at B factories to date is often attributed to the significant negative order-α_{s} correction. In this work we compute the O(α_{s}^{2}) correction to this process for the first time. The magnitude of the next-to-next-to-leading order (NNLO) perturbative correction is substantially negative so that the standard nonrelativistic QCD prediction would suffer from an unphysical, negative cross section. This dilemma may be traced in the fact that the bulk contribution of the fixed-order radiative corrections stems from the perturbative corrections to the J/ψ decay constant. We thus implement an improved nonrelativistic QCD factorization framework, by decomposing the amplitude into the photon-fragmentation piece and the nonfragmentation piece. With the measured J/ψ decay constant as input, which amounts to resumming a specific class of radiative and relativistic corrections to all orders, the fragmentation-induced production rate can be predicted accurately and serves a benchmark prediction. The nonfragmentation type of the amplitude is then computed through NNLO in α_{s} and at lowest order in velocity. Both the O(α_{s}) and O(α_{s}^{2}) corrections in the interference term become positive and exhibit a decent convergence behavior. Our finest prediction is σ(e^{+}e^{-}→J/ψJ/ψ)=2.13_{-0.06}^{+0.30} fb at sqrt[s]=10.58 GeV. With the projected integrated luminosity of 50 ab^{-1}, the prospect to observe this exclusive process at Belle 2 experiment appears to be bright.
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
Second Order systems II
Elimination Kinetics: First-Order and Zero-Order
Drug clearance depends on the rate of drug elimination and its plasma concentration. Another important parameter is a drug's half-life, which is the time required for its concentration to decrease by half. In most cases, drug clearance follows first-order...
Hess's Law
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...

