Related Experiment Video
Updated: Jul 11, 2025

An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
Feasibility, acceptability, and usability of implementing a medical device-related pressure injury algorithm for
Jennifer N Miller1, Susan A Barnason1, Kaitlin A Rogge1
1University of Nebraska Medical Center, College of Nursing, Lincoln, NE 68588, United States.
Objectives:
Describe the feasibility, acceptability, and usability of implementing a nurse-led intervention to prevent medical device-related pressure injury in critical care patients using non-invasive ventilation during hospitalization.
Study Design:
A quality improvement project, using a descriptive single-arm study design with convenience sampling.
Setting And Participants:
This study was conducted at a Midwestern medical center with 640 beds (two hospital campuses). After an educational session, the nurse-led algorithm for non-invasive ventilation medical device-related pressure injury prevention was implemented in two critical care nursing units (cardiac medical progressive care and neurotrauma intensive care unit). Nursing staff were full or part-time critical care nurses.
Main Outcome Measures:
Feasibility, acceptability, and usability of the non-invasive ventilation medical device-related pressure injury algorithm were measured (bedside rounding and pre/post System Usability Scale).
Results:
Thirty-five nurses (52.2 %) completed a pre-educational survey; 8 (11.2 %) completed a post-survey. The total mean pre-survey score was 70.7 (SD ± 13.6) and the post-survey mean score was 71.3(SD ± 19.6). There was a statistically significant increase in the post-survey mean score {Χ2 (1, N = 43) = 43.5, p <.05}, however, the 0.06 increase was not clinically meaningful. Bedside rounding interviews (n = 22) indicated 82 % (n = 18) of the nurses used the algorithm. The SUS tool mean score was 83.3 (10.73) pre-implementation (n = 21); and 85.63 (8.26) post-implementation (n = 5), indicating clinical usability of the algorithm pre- and post-implementation.
Conclusion:
The feasibility, acceptability, and usability of implementing a medical device-related pressure injury algorithm for critically ill patients using non-invasive ventilation were demonstrated during this study. More nursing research is needed to develop scalable interdisciplinary clinical algorithms to reduce medical device-related pressure injuries in patients using non-invasive ventilation.
Implications For Clinical Practice:
This study focused on the bedside usability of the algorithm in a clinical setting. Implementing this nursing-developed algorithm created an interdisciplinary framework in which nursing assessment may guide clinical care.
More Related Videos
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
06:45Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Published on: May 2, 2025
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings