Related Experiment Video
Updated: Jul 11, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Comparing Low Volume Versus Conventional Volume of Polyethylene Glycol for Bowel Preparation during Colonoscopy: A
Muhammad Faeid Othman1,2,3, Andee Dzulkarnaen Zakaria1,2,3, Maya Mazuwin Yahya1,2,3
1Department of Surgery, School of Medical Science, Universiti Sains Malaysia, Kelantan, Malaysia.
Background:
Polyethylene glycol (PEG) solution is widely used as a colonoscopic bowel cleaning agent, although some patients are intolerant due to the need for ingesting large solution volumes and unpleasant taste. A low-volume solution may enhance patient tolerability and compliance in bowel preparation. Accordingly, this study compared the effectiveness of two difference PEG volumes for bowel preparation before colonoscopy in terms of bowel cleanliness, completeness of colonoscopy, patient tolerability and colonoscopy duration.
Methods:
Using a prospective randomised controlled single-blinded study design, 164 patients scheduled for colonoscopy were allocated to two groups (n = 82 patients in each) to receive either the conventional PEG volume (3 L, control group) or the low volume (2 L, intervention group). The Boston Bowel Preparation Scale (BBPS), a validated scale for assessing bowel cleanliness during colonoscopy, was used to score bowel cleanliness in three colon segments. Secondarily, colonoscopy completeness, tolerability to drinking PEG and the duration of colonoscopy were compared between the groups.
Results:
There were no statistically significant differences between the two intervention groups in terms of bowel cleanliness (P = 0.119), colonoscopy completion (P = 0.535), tolerability (P = 0.190) or the amount of sedation/analgesia required (midazolam, P = 0.162; pethidine, P = 0.708). Only the duration of colonoscopy differed between the two groups (longer duration in the control group, P = 0.039).
Conclusion:
Low-volume (2 L) PEG is as effective as the standard 3 L solution in bowel cleaning before colonoscopy; however, the superiority of either solution could not be established.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...

