Related Experiment Video
Updated: Jul 11, 2025

Measuring the pH, Redox Chemistries, and Degradative Capacity of Macropinosomes using Dual-Fluorophore Ratiometric Microscopy
Published on: August 19, 2021
Colorimetric and fluorometric dual-mode determination of hypochlorite based on redox-mediated quenching
Ali O AlQarni1, Ashraf M Mahmoud1, Ramadan Ali2,3
1Department of Pharmaceutical Chemistry, College of Pharmacy, Najran University Najran 11001 Saudi Arabia.
Abstract:
We have successfully created a dual-modal probe, labeled as of iron(ii)-ortho-phenanthroline/N, S@g-CDs, which combines both fluorometric and colorimetric techniques for the accurate and sensitive detection of hypochlorite (ClO-). The mechanism behind this probe involves the fluorescence quenching interaction between nitrogen and sulfur co-doped green emissive carbon dots (N, S@g-CDs) and the iron(ii)-ortho-phenanthroline chelate, utilizing both the inner filter effect and redox processes. As the concentration of ClO- increases, the iron(ii) undergo oxidation to iron(iii) as follows: Fe(ii) + 2HClO = Fe(iii) + Cl2O + H2O, leading to the restoration of N, S@g-CDs fluorescence. Simultaneously, the color of the system transitions gradually from red to colorless, enabling colorimetric measurements. In the fluorometric method with an excitation wavelength of 370 nm, the ClO- concentration exhibits a wide linear correlation with fluorescence intensity ranging from 0.07 to 220 μM. The detection limit achieved in this method is 0.02 μM (S/N = 3). In contrast, the colorimetric method exhibits a linear range of 1.12 to 200 μM, with a detection limit of 0.335 μM (S/N = 3). The proposed selective absorbance for this method is 510 nm. The probe has been effectively utilized for the detection of ClO- in various samples, including water and milk samples. This successful application showcases its potential for determining ClO- in complex matrices, highlighting its broad range of practical uses.
More Related Videos
04:53Detection of Total Reactive Oxygen Species in Adherent Cells by 2',7'-Dichlorodihydrofluorescein Diacetate Staining
Published on: June 23, 2020
12:08Monitoring the Reductive and Oxidative Half-Reactions of a Flavin-Dependent Monooxygenase using Stopped-Flow Spectrophotometry
Published on: March 18, 2012
Related Concept Videos
Redox Titration: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Redox Titration: Iodimetry and Iodometry
Redox Titration: Other Oxidizing and Reducing Agents
Photoluminescence: Applications
Indicators