Related Experiment Video
Updated: Jul 11, 2025

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Novel 3-arm wait-list controlled trial designs together with mixed-effects analysis improve precision of treatment
Xiangmei Ma1, Yin Bun Cheung1,2,3
1Centre for Quantitative Medicine, Duke-NUS Medical School, Singapore, Singapore.
Abstract:
Clinical trialists have long been searching for approaches to increase statistical power without increasing sample size. Conventional wait-list controlled (WLC) trials are limited to two trial arms and two or three repeated measurements per person. These features limit statistical power. Furthermore, their analysis is usually based on analysis of covariance or mixed effects modelling, with a focus on estimating treatment effect at one time-period after initiation of therapy. We propose two 3-arm WLC trial designs together with a mixed-effects analysis framework. The designs require three or four repeated measurements per person. The analytic framework defines up to three treatment effect estimands, representing the effects at one to three time-periods after initiation of therapy. The precision (inverse of variance) of the treatment effect estimators in the new and conventional trial designs are analytically derived and evaluated in simulations. The results are interpreted in the context of a cognitive training trial in older people. The proposed designs and analysis methods increase the precision level of treatment effect estimators as compared to conventional designs and analyses. Given a target level of statistical power, the proposed methods require a smaller number of participants per trial than the conventional methods, without necessarily increasing the number of measurements per trial. Furthermore, the proposed analytic framework sheds light on the treatment effects at different times after initiation of therapy, which is not usually considered in conventional WLC trial analysis. In situations that a WLC trial is appropriate, the 3-arm designs are useful alternatives to existing 2-arm designs.
More Related Videos
06:55Inverse Probability of Treatment Weighting Propensity Score using the Military Health System Data Repository and National Death Index
Published on: January 8, 2020
13:54A Workflow for Lipid Nanoparticle LNP Formulation Optimization using Designed Mixture-Process Experiments and Self-Validated Ensemble Models SVEM
Published on: August 18, 2023
Related Concept Videos
Comparing the Survival Analysis of Two or More Groups
Randomized Experiments
Simple randomization
Simple...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Group Design
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Blinding