Related Experiment Video
Updated: Jul 11, 2025

Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access
Published on: November 19, 2020
Biomimetic Stents for Infrainguinal Peripheral Arterial Disease: Systematic Review and Meta-Analysis
Sarah Jane Messeder1, Gabriel López-Peña2, Coral Pepper3
1Department of Cardiovascular Sciences, University of Leicester, NIHR Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK; Leicester Vascular Institute, University Hospitals of Leicester, Glenfield Hospital, Leicester, UK; British Heart Foundation, Clinical Research Training Fellow, Leicester, UK.
Objective:
Biomimetic stents are peripheral infrainguinal self expanding stents that mimic the anatomy of the vasculature and artery movement. They are indicated for use in infrainguinal arteries. This research aimed to synthesise all current evidence on the use of biomimetic stents as adjuncts for endovascular treatment of infrainguinal peripheral arterial disease (PAD), helping to guide clinical decision making.
Data Sources:
MEDLINE, Embase, CINAHL and Cochrane databases.
Review Methods:
Random effects meta-analysis following PRISMA guidelines (PROSPERO registration CRD42022385256). Study quality was assessed using the Joanna Briggs Institute critical appraisal tools checklist, and certainty assessment through the Grading of Recommendations, Assessment, Development and Evaluation (GRADE). Endpoints included primary patency, target lesion revascularisation, stent fracture, secondary patency, and Death at one year.
Results:
In total, 37 studies were included in the meta-analysis (33 cohort studies, two case series, and two randomised controlled trials [RCTs]), representing 4 480 participants. Of these, 34 studies included data on the Supera (81.5% of participants) and three studies reported data on the BioMimics 3D (18.5% of participants) stents. The pooled primary patency rate of 33 studies at one year follow up was 81.4% (95% confidence interval [CI] 78.7 - 83.9%), and the pooled target lesion revascularisation rate of 18 studies at one year was 12.2% (95% CI 9.6 - 15.0%). The certainty of evidence outcome rating as qualified by GRADE was very low for both. Only one study reported a positive stent fracture rate at one year follow up of 0.4% with a certainty of evidence outcome of low.
Conclusion:
Using biomimetic stents for infrainguinal PAD may be associated with acceptable one year primary patency and target lesion revascularisation rates, with a near negligible one year stent fracture rate. Their use should be considered in those presenting with infrainguinal PAD undergoing endovascular revascularisation. A RCT is necessary to determine their clinical and cost effectiveness.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation